Hi @amisapta15,
I was checking the FVF block generator, and seems like when we are using the device with multipliers, the routing between fets are coliding with the internal routing of the multipliers causing an unintentional short circuit.
Although the nets are the same, the displacement produces a reduction of the metal spacing generating a DRC error:
Maybe we can move that connection to the right side and make it conditional according to the type of placement.
What do you think?
Thanks,
Luighi
Hi @amisapta15,
I was checking the FVF block generator, and seems like when we are using the device with multipliers, the routing between fets are coliding with the internal routing of the multipliers causing an unintentional short circuit.
Although the nets are the same, the displacement produces a reduction of the metal spacing generating a DRC error:
Maybe we can move that connection to the right side and make it conditional according to the type of placement.
What do you think?
Thanks,
Luighi