The generic Helium kernels, used by arm_fir_q15 for numTaps > 32 and by
arm_fir_q7 for numTaps > 64, give wrong results and access memory outside
the documented buffers. The existing FIR tests use at most 25 taps, so they
never reach these kernels.

Defects

  • Tail of the block (blockSize & 3 equal to 2 or 3) : outputs 1 and 2 were
    computed from the wrong delayed samples (offsets 2 and 4 for Q15, 4 and 8
    for Q7, instead of 1 and 2). For Q15, the tail of 3 samples also shifted
    the accumulators twice.
  • For each group of 4 outputs, a full vector of input samples (8 for Q15,
    16 for Q7) was copied into the state and both pointers were advanced by
    the vector length : pSrc was read past the end of the block and
    pState was written past its documented size
    (numTaps + blockSize - 1).
  • The final copy of the history copied numTaps samples instead of
    numTaps - 1, reading one sample past the documented state size.

mdionisio and others added 2 commits November 14, 2026 19:18
The existing FIR tests use at most 25 taps, so they never reach the
generic Helium kernels of arm_fir_q15 (numTaps > 32) and arm_fir_q7
(numTaps > 64).

New tests test_fir_long_q15 and test_fir_long_q7 in the FIR Q15 and
FIR Q7 suites:

- numTaps 34 to 200 (Q15) and 65 to 200 (Q7), blockSize 1 to 8, 13 and
  16 (all the values of blockSize & 3), 3 successive calls on the same
  instance
- references computed with an exact model of the fixed point FIR
  (PatternGeneration/FIR.py), compared bit exact
- guard samples after the documented size of the state buffer to
  detect writes beyond it

On Cortex-M55 these tests fail with the current Helium kernels.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The generic Helium kernels, used by arm_fir_q15 for numTaps > 32 and by
arm_fir_q7 for numTaps > 64, had three defects:

- the tail of the block (blockSize & 3 equal to 2 or 3) computed the
  outputs 1 and 2 from the wrong delayed samples (offsets 2 and 4 for
  Q15, 4 and 8 for Q7, instead of 1 and 2), and the Q15 tail of 3
  samples shifted the accumulators twice
- for each group of 4 outputs, a full vector of input samples (8 for
  Q15, 16 for Q7) was copied into the state and both pointers were
  advanced by the vector length: pSrc was read past the end of the
  block and pState was written past its documented size
- the final copy of the history copied numTaps samples instead of
  numTaps - 1, reading one sample past the documented state size

Only the input samples consumed by the outputs are now copied, with
predicated loads and stores.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>