Owner

Home Assistant core runs the hr_energy_qube integration under strict typing, and the platinum quality scale asks for a typed library. The library already ships py.typed, but mypy --strict reported 5 errors in client.py. This fixes them and adds a strict mypy step to CI so it stays that way.

  • read_value() types its register definition as (address, register type, data type, scale, offset), the shape of the tuples in const.py.
  • _decode_registers() accepts the Sequence[int] that pymodbus returns.
  • read_entity() returns float | int | bool | None instead of Any; read_binary_sensor() and read_switch() narrow that to bool | None. All binary sensors and switches are coils or discrete inputs, which already returned a bool, so no return value changes.
  • CI runs mypy --strict src/python_qube_heatpump (mypy pinned to 2.4.0); AGENTS.md lists the command.

No API or behaviour change; version 1.17.1. Core can stay on its ==1.17.0 pin.

@MattieGit
MattieGit merged commit a6fc2be into main Oct 14, 2026
3 checks passed
@MattieGit
MattieGit deleted the strict-typing branch October 14, 2026 19:55