Volume.FromMilliliter(1) is 1 litre (1e-3 m³), 1000× too large: Milli prefix is applied to m³ instead of the litre #286
UnitsGenerator.BuildToBaseFactorExpression applies the magnitude to the dimension's SI base unit. For Volume that base unit is m³, not the litre, so the generated ToBaseFactor is MetricMagnitudes.Milli = 1e-3 m³. That is one litre. The correct factor is 1e-6 m³.
The same pattern gives correct results elsewhere only because those units are prefixed forms of the base unit itself. For example, Gram = Milli × kg = 1e-3 kg is correct, and Millimeter = Milli × m is correct. The litre is not the base unit of Volume, so the prefix alone is wrong here.
Failure scenario
Volume<double>.FromMilliliter(1.0).Value returns 0.001 (m³). It should return 1e-6.
Everything that goes through the unit's factor is off by 1000×: Capacity.FromMilliliter, IUnit.ToBaseFactor, ToBaseFactorAs<T>(), and every In(new Milliliter()).
For example, 5 mL of a dose or reagent comes out as 5 L. No test references Milliliter, so nothing catches this.
Check the other units in units.json that carry a magnitude in dimensions whose base unit is not the unprefixed form of that unit. Any new ones found get the same treatment and a test.
Priority: High. FromMilliliter is off by 1000× and nothing fails, so 5 mL silently becomes 5 L. It flows through ToBaseFactor, In(...) and Capacity, and no test covers it.
Area / suggested assignee:Semantics.SourceGenerators/Metadata/units.json (the Milliliter entry) and UnitsGenerator.BuildToBaseFactorExpression. Owner: @matt-edmondson
Next step: Add "conversionFactor": "LiterToCubicMeters" to Milliliter and regenerate. Then audit every magnitude-bearing unit whose dimension's base unit isn't that unit's unprefixed form, for example other litre-based units or prefixed non-SI units. A generator-side check or a test that round-trips every unit against a known value would stop this class of bug from coming back.
Activity
matt-edmondson commentedon Sep 27, 2026
Triage
FromMilliliteris off by 1000× and nothing fails, so 5 mL silently becomes 5 L. It flows throughToBaseFactor,In(...)andCapacity, and no test covers it.Semantics.SourceGenerators/Metadata/units.json(theMilliliterentry) andUnitsGenerator.BuildToBaseFactorExpression. Owner: @matt-edmondson"conversionFactor": "LiterToCubicMeters"toMilliliterand regenerate. Then audit everymagnitude-bearing unit whose dimension's base unit isn't that unit's unprefixed form, for example other litre-based units or prefixed non-SI units. A generator-side check or a test that round-trips every unit against a known value would stop this class of bug from coming back.Generated by Claude Code