@JanZachmann JanZachmann commented Oct 6, 2026 •

Copy link
Copy Markdown
Contributor

Closes #125

Summary

omnect-os moves from the scripted initramfs to omnect-os-init, an init written in Rust (omnect/meta-omnect#697). The new init writes a different factory-reset result and does not support reset mode 4; omnect/omnect-device-service#207 publishes this result as factory_reset feature version 4. This PR makes omnect-ui follow both changes. It also changes the probe of wifi-commissioning-service.

Factory reset result of feature version 4

  • The factory-reset result types follow the format omnect-device-service publishes with feature version 4: status is a u32 with the codes success, invalid, error, configError and warning plus a catch-all, error and context are null when nothing went wrong, and the new data_wiped flag tells whether the reset had already started to change data. The required omnect-device-service version is >=0.46.1.
  • The domain status enum has two variants that are not a real result. Unknown is the default and means "no result received yet", so the result dialog stays hidden. Unrecognized is the catch-all, so a status code that a later omnect-device-service adds still reaches the user.
  • warning counts as success in the UI: the reset completed, but a partition needed a second format attempt. data_wiped is shown only on a failed result, where the device may be partly wiped and needs another reset.

wifi-commissioning-service probe via service-info

  • GET /api/v1/service-info (wifi-commissioning-service 0.2.0, feat(api): add /api/v1/service-info exposing ble_enabled wifi-commissioning-service#3) is the only availability probe: it returns version, interface name and BLE state in one call. The probe no longer calls /api/v1/status and /api/v1/version.
  • The version requirement works as for omnect-device-service: a semver requirement string (>=0.2.1) and the existing VersionInfo { required, current, mismatch }. WifiAvailability::Unavailable carries version_info: Option<VersionInfo>. None means the probe failed or the version does not parse; the device info shows unknown. An empty interface name also makes the service unavailable.
  • An old wifi-commissioning-service does not block the UI: WiFi is optional, so the mismatch shows only in the WiFi line of the device info. ble_enabled is only logged.

Factory reset mode 4 removed

  • The web API no longer accepts factory-reset mode 4; a request with it is rejected when the body is deserialized. Modes 1 to 3 are unchanged.

Reason

With omnect/omnect-device-service#207, error is null after a successful reset, but omnect-ui requires a String. So every factory-reset result fails to deserialize, and the UI shows a parse error instead of the result. The status codes were renamed and extended in the same change, so the old repr(u8) enum with four variants cannot name what the device reports.

The service-info probe needs one request instead of two. With the same requirement string and VersionInfo as omnect-device-service, both services report an unsupported version in the same way. The required version >=0.2.1 is the released wifi-commissioning-service tag.

Mode 4 ran a customer wipe script inside the scripted initramfs. omnect-os-init has no such script and answers mode 4 with Invalid, a reset that never runs. Rejecting the value here keeps the request from being sent at all.

This PR, omnect/omnect-device-service#207 and omnect/meta-omnect#697 have to reach a release together, so no component offers a mode the device refuses, and the UI can read the result the device reports.

…eature version 4

Adapt the factory-reset result wire types to the shape omnect-device-service
publishes on FactoryResetV1 with factory_reset feature version 4:

- status is a u32 with the codes success, invalid, error, configError and
  warning, plus a catch-all so a future code parses instead of failing the
  whole update
- error and context arrive as null when nothing went wrong
- data_wiped tells whether the destructive phase had already started

Raise the required omnect-device-service version to 0.46.0.

Signed-off-by: Jan Zachmann 50990105+JanZachmann@users.noreply.github.com
Use the service-info endpoint as the single availability probe. It returns
version, interface name and live BLE state in one call, replacing the separate
status and version requests.

Report the version requirement the same way as for omnect-device-service: a
semver requirement string plus a required/current/mismatch triple. Unlike the
device service a stale wifi-commissioning-service does not block the UI, since
WiFi is optional and gated on the socket being present — the mismatch shows in
the WiFi section of the device info.

Signed-off-by: Jan Zachmann 50990105+JanZachmann@users.noreply.github.com
service-info reports the version, so the separate version request has no
caller left. Also correct the version floor comment: 0.2.0 already serves
service-info, the floor tracks the released tag.

Signed-off-by: Jan Zachmann 50990105+JanZachmann@users.noreply.github.com
Mode 4 ran a customer-supplied wipe hook in the initramfs. The hook is gone
and the initramfs no longer accepts the mode: a trigger carrying it fails to
parse, the device boots normally and no result is reported at all, so a reset
requested with it would never be answered.

The web API rejects the value now, instead of passing it on.

Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>
Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>
Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>
Fixes RUSTSEC-2026-0385, RUSTSEC-2026-0382 and RUSTSEC-2026-0383.

Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>
Move the wcs availability decision into a pure function with a test per
branch and share one version check with the ods client. The result dialog
names an unknown status, shows a warning's context, and no longer says a
new reset fixes a failure after data was changed. Test status codes the UI
does not know, reject mode 4, and cut comments and tests that add nothing.

Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>

@JoergZeidler JoergZeidler left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Review of the three changes. All contracts are followed across core, generated types and the Vue shell; no correctness bugs. cargo +nightly fmt and cargo test --features mock pass locally. clippy could not run clean here because of a pre-existing unknown lint: clippy::unused_async_trait_impl in api.rs/certificate.rs (outside this PR) with no toolchain pinned — not a PR issue. tsc/biome/e2e were not run (no bun in my environment).

Inline comments hold the per-file findings. Two more that have no diff line to anchor to:

  • Low — project-context.md not updated. The new backend module src/backend/src/version.rs is not in the "Project Structure" tree. The file's own rule asks for that section to be updated on a structure change.
  • Minor — README.md:187 wording. It says the WiFi entry shows the "minimum required version"; the UI now shows current (required: >=X). Small wording drift, not a contract break.

Unverified (no action needed, just noting): the three RUSTSEC advisory IDs in the dep-bump commit are not checked (no cargo-audit config / no network), and the external service payloads (factory_reset v4, /api/v1/service-info) are checked against this repo's client and tests plus the named producer PRs, not the other repos' source.

Comment thread src/app/src/types/wifi.rs Resolved
Comment thread src/ui/tests/factory-reset.spec.ts Resolved
Comment thread src/ui/tests/factory-reset.spec.ts Resolved
…hecks

wifi-commissioning-service always sends status "ok" on HTTP 200 for
service-info; a failure is a non-2xx answer, which is already reported as
unavailable. The field is not needed.

Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>

@JoergZeidler JoergZeidler left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

All round-1 findings resolved in 718ecf6. Verified locally: cargo +nightly fmt --check and cargo test --features mock pass. Dropping the unused status field is serde-safe (no deny_unknown_fields), and the two e2e negative assertions are correct. clippy/tsc/biome/e2e not re-run in my environment; trusting your reported runs.

JanZachmann added a commit to omnect/omnect-device-service that referenced this pull request Nov 4, 2026
…act (#207)

Closes #205

## Summary

omnect-os moves from the scripted initramfs to
[omnect-os-init](https://github.com/omnect/omnect-os-init), an init
written in Rust (omnect/meta-omnect#697). The init writes the
factory-reset result to
`/run/omnect-device-service/omnect-os-initramfs.json` in a new JSON
format. This PR makes omnect-device-service read this format and report
it to the twin.

- Reads the key `factory_reset`. A result under the old key
`factory-reset` is unusable: it is logged as an error and reported as
`null`. A `null` under the old key is a normal boot.
- The status codes have the omnect-os-init names: `0` success, `1`
invalid, `2` error, `3` config error, and the new `4` warning (the reset
worked, but a partition needed a second `mkfs`). The status is a `u32`,
as omnect-os-init writes it. A status code this version does not know is
reported as it is, and the raw result is logged as a warning.
- `error` and `context` are optional, `paths` defaults to an empty list.
`data_wiped` is required: a result without it is unusable and reported
as `null`, because a missing value must not read as a safe abort.
- Reports `data_wiped`: on error it tells a safe abort from a failure
after data was already wiped.
- Reports `error` and `context` as `null` instead of leaving them out:
twin reports are merge patches, so a missing key would keep the value of
a previous result.
- The `factory_reset` feature version is 4, because the reported result
changed. The crate version is 0.46.1.
- Mode 4 is no longer accepted: the init does not support it, so a
request with mode 4 would come back as `Invalid`, a reset that never
runs.
- The test files have the real omnect-os-init output.
`testfiles/positive/contract` holds copies of the status files that
omnect-os-init writes for every factory reset result (its
`tests/contract`, omnect/omnect-os-init#40); a test parses each one and
compares every field.
- The README says that a result from before feature version 4 stays in
the twin until the next reset, and that `preserve` accepts only the
reported keys.
- README and `update_validation.md` link the initramfs docs in
omnect-os-init (`docs/usage.md`) instead of meta-omnect and the legacy
scripts. The README documents the result fields, and that `preserve` is
mandatory, as the parser already requires.
- `update_validation.md` says that omnect-os-init deletes
`update_validation_conf.json` on every boot without update validation
(omnect/omnect-os-init#40), so a config written by hand is gone after
the next reboot.

## Reason

The parser did not match the omnect-os-init format: it read the key
`factory-reset` and required an `error` string. So the result of the
init was unusable and never reached the twin. See #205 for the full list
of differences.

omnect-os-init tests that it writes exactly the contract files, and this
repo tests that it parses them. So a format change on one side fails a
test once the copies are updated.

omnect-ui reads the published result and must follow the new format and
the removed mode 4: omnect/omnect-ui#132. The local web service keeps
the channel `FactoryResetV1` and the route `/factory-reset/v1`, although
the payload changed and mode 4 is rejected. An omnect-ui without
omnect/omnect-ui#132 gets no signal about this. The only safeguard is
that this PR, omnect/meta-omnect#697 and omnect/omnect-ui#132 reach a
release together; omnect-ui#132 also requires ods `>=0.46.1`.

---------

Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>
@JanZachmann
JanZachmann merged commit 986034d into omnect:main Nov 4, 2026
1 check passed
JanZachmann added a commit that referenced this pull request Nov 4, 2026
## Summary

- Bump the workspace version from 1.2.8 to 1.3.0 (`Cargo.toml`,
`Cargo.lock`).

## Reason

#132 was merged without a version bump. The QA pipeline then tries to
tag 1.2.8 again and fails, because that tag already exists. #132 is a
feature (factory reset feature version 4, no reset mode 4), so the minor
version goes up.

Signed-off-by: Jan Zachmann <50990105+JanZachmann@users.noreply.github.com>
JanZachmann added a commit to omnect/meta-omnect that referenced this pull request Nov 4, 2026
…697)

## Summary

omnect-os moves from the scripted initramfs to
[omnect-os-init](https://github.com/omnect/omnect-os-init), an init
written in Rust. This PR is the main integration step: it builds the
init, installs it as `/init` and removes the scripted initramfs
(`init.d/*` from `omnect-os-initramfs-scripts`).

- `omnect-os-init`: Cargo features follow the machine and distro (`grub`
or `uboot`, the partition table from `OMNECT_PART_TABLE`,
`factory-reset`, `resize-data`, `persistent-var-log`, `release-image`,
`flash-mode-2`, `flash-mode-2-direct` when
`OMNECT_FLASH_MODE_2_DIRECT_FLASHING` is `1`, `flash-mode-3`, `rtc` from
the machine feature, and `early-modules` when `OMNECT_EARLY_MODULES` is
set). The partition and bootloader constants that flash mode 1 needs are
exported into the build; for flash mode 2 also the boot partition offset
and size and `OMNECT_USER_ID`.
- `OMNECT_PART_TABLE` (`gpt` or `dos`, default `gpt`) selects the
partition table the init is built for; a machine whose wks file uses
`--ptable msdos` sets `dos`.
- `OMNECT_USER_ID` (uid and gid of the omnect user) is a distro
variable, so the init recipe and `omnect_user.bbclass` share one value.
- `omnect-os-initramfs`: installs the tools the init calls (`bash` for
the debug shell on non-release images, `e2fsprogs`, `dosfstools`,
`util-linux-sfdisk`, `util-linux-blkid` on GRUB machines, `efibootmgr`
on EFI machines, `dhcpcd` and `base-passwd` for flash modes 2 and 3,
`dropbear` and the omnect user for flash mode 2, `curl` and
`ca-certificates` for flash mode 3). It drops the legacy script
packages, the initramfs-framework modules, `os-release`, `jq`, `kmod`,
`util-linux-uuidgen`, `bmaptool` and `xz`. `dhcpcd` is built without
udev: it runs only in the initramfs, where udevd does not run, so it no
longer pulls udev into the initramfs. The `fsck.fat` links in `/sbin`
are created only when `/sbin` is not merged into `/usr/sbin`; on a
merged image they replaced `fsck.fat` with a link to itself, so the boot
partition was never checked.
- GRUB passes `bootpart_fsuuid` instead of `rootblk`, so the init finds
its disk by the filesystem UUID of the boot partition (partition 1, read
with `probe`). A flash mode 1 clone gets a new boot volume ID
([omnect-os-init#38](omnect/omnect-os-init#38));
the rootfs UUID would be the same on the clone and its source.
- GRUB boots from the disk it was loaded from (taken from `$cmdpath`,
which needs the `regexp` module), not from `hd0`. `hd0` is the first
disk of the firmware: with a flash mode 1 clone and its source both
attached, GRUB read the grubenv of the clone but loaded kernel and
rootfs from the source.
- U-Boot declares every environment variable the OS writes at runtime as
writable (`omnect_first_boot_done`, `omnect_fsck_*`,
`omnect_factory_reset_last_error`, `flash-mode-url`,
`flash-mode-url-sha256`), so a `saveenv` in `omnect_update_flow` keeps
them. `data-mount-options` and `resized-data` are no longer listed,
because the init reads neither.
- `u-boot-scr`: the boot script no longer appends the literal text
`None` to `bootargs` when `OMNECT_APPEND_1ST_BOOT` is unset, as on
developer images.
- `OMNECT_EARLY_MODULES` lists the kernel modules the init loads before
`switch_root` (`imx_sdma` on phytec-imx8mm). It selects the
`early-modules` feature, and the new package
`omnect-os-init-early-modules` installs the list into the rootfs as
`/etc/omnect/early-modules.d/omnect.conf`. The `omnect-os-init` recipe
is built per machine, because its features and `build.rs` read machine
settings. rpi kernels build compressed modules, so they get
`CONFIG_MODULE_DECOMPRESS` when the variable is set.
- `omnect-base-files` adds the mount point `/mnt/rootCurrentPrivate`,
where the init bind-mounts the root filesystem. Its tmpfiles config
creates `/mnt/cert/ca` and `/mnt/cert/priv` (`d` instead of `z`),
because the init does not create them.
- The busybox `poweroff` config is removed; the init powers off itself.
- Removed with the scripted initramfs:
- The recipe `omnect-os-initramfs-scripts`. A layer with a `.bbappend`
for it no longer parses, and own `init.d` scripts are no longer
possible.
- Factory reset wipe mode 4, a custom wipe added by such a `.bbappend`.
A request with `mode` 4 now gets status 1.
- The bootloader variable `data-mount-options`; the data partition is
always mounted with the default options.
- An optional `preserve`: the factory-reset request must now contain it,
else it gets status 3.
- `omnect-device-service` reads the factory-reset result the init writes
([omnect-device-service#207](omnect/omnect-device-service#207)).
- The expected bootloader checksums of genericx86-64, rpi and
phytec-imx8mm follow the changed bootloader inputs.
- README and `doc/`: keep the build settings and link to the
[omnect-os-init
docs](https://github.com/omnect/omnect-os-init/blob/main/docs/usage.md)
for the behaviour of flash modes, factory reset, filesystem check and
the status file.

## Reason

The initramfs moves from shell scripts to one Rust binary, for typed
error handling, a defined result contract towards omnect-device-service,
and unit tests for the boot, factory-reset and flash paths.

- The `omnect-os-init` recipe builds the released version 0.1.0. It
contains
[omnect-os-init#40](omnect/omnect-os-init#40),
which keeps what the scripted initramfs did: `/run` without suid and
device files, the links of `create-fs-links.txt`, the persistent logs in
`/mnt/data/log`, and the restored directories with their owner and mode.
- The `omnect-device-service` recipe builds the released version 0.46.1,
which contains
[omnect-device-service#207](omnect/omnect-device-service#207).
- [omnect-ui#132](omnect/omnect-ui#132) reads
the new factory-reset result and no longer offers mode 4. The three PRs
have to reach a release together.
- The bootloader version changes on every machine, because
`omnect_env.h` and the GRUB config are bootloader inputs (on
phytec-imx8mm the boot script is one too); devices get a bootloader
update with this image. A layer whose bootloader checksum covers
`recipes-bsp/u-boot/u-boot/*` needs a new expected value at the same
time.

---------

Signed-off-by: Jan Zachmann 50990105+JanZachmann@users.noreply.github.com